Corrective Actions

| 17
Name Reasoning
variable "ALKYZZXX" missing the following attributes:
  • coverage_content_type
variable "CONDUCTIVITY_RATIO" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "DOXYZZ01" missing the following attributes:
  • coverage_content_type
variable "NTRIZZXX" missing the following attributes:
  • coverage_content_type
variable "PHOSAAZX" missing the following attributes:
  • coverage_content_type
variable "PHXXPR01" missing the following attributes:
  • coverage_content_type
  • units
variable "PSALST01" missing the following attributes:
  • coverage_content_type
variable "Phosphate_inorg_" missing the following attributes:
  • coverage_content_type
variable "SIGTEQST" missing the following attributes:
  • coverage_content_type
variable "SLCAZZXX" missing the following attributes:
  • coverage_content_type
  • long_name
variable "SO4XCLP1" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "SSALST01" missing the following attributes:
  • coverage_content_type
variable "TEMPP681" missing the following attributes:
  • coverage_content_type
  • long_name
variable "TEMPPR01" missing the following attributes:
  • coverage_content_type
variable "TEMPS601" missing the following attributes:
  • coverage_content_type
variable "TEMPS901" missing the following attributes:
  • coverage_content_type
variable "Vitamin_B12" missing the following attributes:
  • coverage_content_type
  • standard_name
| 2
Name Reasoning
Global Attributes
  • acknowledgment/acknowledgement not present
  • comment not present
  • project not present
  • processing_level not present
  • geospatial_bounds not present
  • time_coverage_duration not present
  • time_coverage_resolution not present
  • geospatial_bounds_crs not present
  • geospatial_bounds_vertical_crs not present
date_created_is_iso
  • Attr date_created is not present

Corrective Actions

| 2
Name Reasoning
§3.1 Units
  • units for TEMPS601, "degrees_celsius (IPTS68)" are not recognized by UDUNITS
  • units for CONDUCTIVITY_RATIO, "n/a" are not recognized by UDUNITS
  • Units "None" for variable PHXXPR01 must be convertible to canonical units "1"
  • units for TEMPS901, "degrees_celsius (ITS-90)" are not recognized by UDUNITS
  • units for TEMPP681, "degrees_celsius (IPTS68)" are not recognized by UDUNITS
  • Units "mmol/m" for variable ALKYZZXX must be convertible to canonical units "mol m-3"
§3.5 Flags
  • Quality_Flag_Temp's flag_values must be independent and can not be repeated
  • Quality_Flag_Sali's flag_values must be independent and can not be repeated
  • Quality_Flag_Oxyg's flag_values must be independent and can not be repeated
  • flag_values (<class 'numpy.int32'>) must be the same data type as Quality_Flag_Oxyg (<class 'numpy.float32'>)
  • Quality_Flag_Phos's flag_values must be independent and can not be repeated
  • flag_values (<class 'numpy.int32'>) must be the same data type as Quality_Flag_Phos (<class 'numpy.float32'>)
  • Quality_Flag_Nitr's flag_values must be independent and can not be repeated
  • flag_values (<class 'numpy.int32'>) must be the same data type as Quality_Flag_Nitr (<class 'numpy.float32'>)
  • Quality_Flag_Vita's flag_values must be independent and can not be repeated
  • Quality_Flag_Sili's flag_values must be independent and can not be repeated
  • flag_values (<class 'numpy.int32'>) must be the same data type as Quality_Flag_Sili (<class 'numpy.float32'>)
  • Quality_Flag_pH's flag_values must be independent and can not be repeated
  • flag_values (<class 'numpy.int32'>) must be the same data type as Quality_Flag_pH (<class 'numpy.float32'>)
  • Quality_Flag_Alka's flag_values must be independent and can not be repeated
  • flag_values (<class 'numpy.int32'>) must be the same data type as Quality_Flag_Alka (<class 'numpy.float32'>)
  • Quality_Flag_Phosphate_inorg's flag_values must be independent and can not be repeated
  • flag_values (<class 'numpy.int32'>) must be the same data type as Quality_Flag_Phosphate_inorg (<class 'numpy.float32'>)
  • Quality_Flag_Sulp's flag_values must be independent and can not be repeated
  • flag_values (<class 'numpy.int32'>) must be the same data type as Quality_Flag_Sulp (<class 'numpy.float32'>)
| 2
Name Reasoning
§2.3 Naming Conventions
  • attribute profile:_Encoding should begin with a letter and be composed of letters, digits, and underscores
  • attribute filename:_Encoding should begin with a letter and be composed of letters, digits, and underscores
  • attribute agency:_Encoding should begin with a letter and be composed of letters, digits, and underscores
  • attribute mission_id:_Encoding should begin with a letter and be composed of letters, digits, and underscores
  • attribute event_number:_Encoding should begin with a letter and be composed of letters, digits, and underscores
  • attribute cruise:_Encoding should begin with a letter and be composed of letters, digits, and underscores
  • attribute project:_Encoding should begin with a letter and be composed of letters, digits, and underscores
  • attribute scientist:_Encoding should begin with a letter and be composed of letters, digits, and underscores
  • attribute platform_name:_Encoding should begin with a letter and be composed of letters, digits, and underscores
  • attribute instrument_type:_Encoding should begin with a letter and be composed of letters, digits, and underscores
  • attribute geographical_area:_Encoding should begin with a letter and be composed of letters, digits, and underscores
  • attribute station:_Encoding should begin with a letter and be composed of letters, digits, and underscores
§2.6 Attributes
  • §2.6.1 Conventions global attribute does not contain "CF-1.6"