Corrective Actions

| 3
Name Reasoning
§3.1 Units
  • Units "None" for variable turbidity_med must be convertible to canonical units "1"
  • Units "None" for variable turbidity_avg must be convertible to canonical units "1"
§3.3 Standard Name
  • standard_name aggregate_quality_flag is not defined in Standard Name Table v70. Possible close match(es): ['quality_flag']
  • standard_name aggregate_quality_flag is not defined in Standard Name Table v70. Possible close match(es): ['quality_flag']
  • standard_name aggregate_quality_flag is not defined in Standard Name Table v70. Possible close match(es): ['quality_flag']
  • standard_name aggregate_quality_flag is not defined in Standard Name Table v70. Possible close match(es): ['quality_flag']
  • standard_name aggregate_quality_flag is not defined in Standard Name Table v70. Possible close match(es): ['quality_flag']
  • standard_name aggregate_quality_flag is not defined in Standard Name Table v70. Possible close match(es): ['quality_flag']
§4.3 Vertical Coordinate
  • elevation: vertical coordinates not defining pressure must include a positive attribute that is either 'up' or 'down'
| 4
Name Reasoning
§2.3 Naming Conventions
  • attribute station:_Encoding should begin with a letter and be composed of letters, digits, and underscores
  • attribute station_id:_Encoding should begin with a letter and be composed of letters, digits, and underscores
  • attribute station_description:_Encoding should begin with a letter and be composed of letters, digits, and underscores
  • attribute last_updated_status:_Encoding should begin with a letter and be composed of letters, digits, and underscores
  • attribute last_updated_lvl_status:_Encoding should begin with a letter and be composed of letters, digits, and underscores
  • attribute pls_lvl_qc:_Encoding should begin with a letter and be composed of letters, digits, and underscores
  • attribute pls_temp_qc:_Encoding should begin with a letter and be composed of letters, digits, and underscores
  • attribute discharge_rate_qc:_Encoding should begin with a letter and be composed of letters, digits, and underscores
  • attribute discharge_volume_qc:_Encoding should begin with a letter and be composed of letters, digits, and underscores
  • attribute turbidity_qc:_Encoding should begin with a letter and be composed of letters, digits, and underscores
  • attribute turbidity_ntu_qc:_Encoding should begin with a letter and be composed of letters, digits, and underscores
§2.6 Attributes
  • §2.6.1 Conventions global attribute does not contain "CF-1.6"
§7.3 Cell Methods
  • pls_lvl_min:cell_methods contains an invalid method: min
  • pls_lvl_max:cell_methods contains an invalid method: max
  • pls_lvl_std:cell_methods contains an invalid method: std
  • pls_temp_min:cell_methods contains an invalid method: min
  • pls_temp_max:cell_methods contains an invalid method: max
  • pls_temp_std:cell_methods contains an invalid method: std
  • discharge_rate_min:cell_methods contains an invalid method: min
  • discharge_rate_max:cell_methods contains an invalid method: max
  • discharge_volume_min:cell_methods contains an invalid method: min
  • discharge_volume_max:cell_methods contains an invalid method: max
§9.1 Features and feature types
  • record is not a timeseries, it is detected as a point
  • pls_lvl_ql is not a timeseries, it is detected as a point
  • pls_lvl_uql is not a timeseries, it is detected as a point
  • pls_lvl is not a timeseries, it is detected as a point
  • pls_lvl_avg is not a timeseries, it is detected as a point
  • pls_lvl_min is not a timeseries, it is detected as a point
  • pls_lvl_max is not a timeseries, it is detected as a point
  • pls_lvl_std is not a timeseries, it is detected as a point
  • pls_temp_ql is not a timeseries, it is detected as a point
  • pls_temp_uql is not a timeseries, it is detected as a point
  • pls_temp is not a timeseries, it is detected as a point
  • pls_temp_avg is not a timeseries, it is detected as a point
  • pls_temp_min is not a timeseries, it is detected as a point
  • pls_temp_max is not a timeseries, it is detected as a point
  • pls_temp_std is not a timeseries, it is detected as a point
  • discharge_rate_ql is not a timeseries, it is detected as a point
  • discharge_rate_uql is not a timeseries, it is detected as a point
  • discharge_rate is not a timeseries, it is detected as a point
  • discharge_rate_min is not a timeseries, it is detected as a point
  • discharge_rate_max is not a timeseries, it is detected as a point
  • discharge_volume_ql is not a timeseries, it is detected as a point
  • discharge_volume_uql is not a timeseries, it is detected as a point
  • discharge_volume is not a timeseries, it is detected as a point
  • discharge_volume_min is not a timeseries, it is detected as a point
  • discharge_volume_max is not a timeseries, it is detected as a point
  • turbidity_ql is not a timeseries, it is detected as a point
  • turbidity_uql is not a timeseries, it is detected as a point
  • turbidity_med is not a timeseries, it is detected as a point
  • turbidity_avg is not a timeseries, it is detected as a point
  • turbidity_ntu_ql is not a timeseries, it is detected as a point
  • turbidity_ntu_uql is not a timeseries, it is detected as a point
  • turbidity_ntu_med is not a timeseries, it is detected as a point
  • turbidity_ntu_avg is not a timeseries, it is detected as a point

Corrective Actions

| 33
Name Reasoning
variable "discharge_rate" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "discharge_rate_max" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "discharge_rate_min" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "discharge_rate_ql" missing the following attributes:
  • coverage_content_type
  • standard_name
  • units
variable "discharge_rate_uql" missing the following attributes:
  • coverage_content_type
variable "discharge_volume" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "discharge_volume_max" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "discharge_volume_min" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "discharge_volume_ql" missing the following attributes:
  • coverage_content_type
  • standard_name
  • units
variable "discharge_volume_uql" missing the following attributes:
  • coverage_content_type
variable "pls_lvl" missing the following attributes:
  • coverage_content_type
  • standard_name
  • units
variable "pls_lvl_avg" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "pls_lvl_max" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "pls_lvl_min" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "pls_lvl_ql" missing the following attributes:
  • coverage_content_type
  • standard_name
  • units
variable "pls_lvl_std" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "pls_lvl_uql" missing the following attributes:
  • coverage_content_type
variable "pls_temp" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "pls_temp_avg" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "pls_temp_max" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "pls_temp_min" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "pls_temp_ql" missing the following attributes:
  • coverage_content_type
  • standard_name
  • units
variable "pls_temp_std" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "pls_temp_uql" missing the following attributes:
  • coverage_content_type
variable "record" missing the following attributes:
  • coverage_content_type
  • standard_name
  • units
variable "turbidity_avg" missing the following attributes:
  • coverage_content_type
  • units
variable "turbidity_med" missing the following attributes:
  • coverage_content_type
  • units
variable "turbidity_ntu_avg" missing the following attributes:
  • coverage_content_type
variable "turbidity_ntu_med" missing the following attributes:
  • coverage_content_type
variable "turbidity_ntu_ql" missing the following attributes:
  • coverage_content_type
  • standard_name
  • units
variable "turbidity_ntu_uql" missing the following attributes:
  • coverage_content_type
variable "turbidity_ql" missing the following attributes:
  • coverage_content_type
  • standard_name
  • units
variable "turbidity_uql" missing the following attributes:
  • coverage_content_type
| 2
Name Reasoning
Global Attributes
  • acknowledgment/acknowledgement not present
  • naming_authority not present
  • comment not present
  • creator_name not present
  • creator_url not present
  • creator_email not present
  • project not present
  • processing_level not present
  • geospatial_bounds not present
  • geospatial_vertical_min not present
  • geospatial_vertical_max not present
  • time_coverage_duration not present
  • time_coverage_resolution not present
  • geospatial_vertical_positive not present
  • geospatial_bounds_crs not present
  • geospatial_bounds_vertical_crs not present
  • publisher_name not present
  • publisher_url not present
  • publisher_email not present
  • source not present
date_created_is_iso
  • Attr date_created is not present