Corrective Actions

| 0
All high priority checks passed!
| 2
Name Reasoning
§2.3 Naming Conventions
  • attribute vessel_id:_Encoding should begin with a letter and be composed of letters, digits, and underscores
  • attribute PC_Date:_Encoding should begin with a letter and be composed of letters, digits, and underscores
  • attribute PC_time:_Encoding should begin with a letter and be composed of letters, digits, and underscores
  • attribute GPS_date:_Encoding should begin with a letter and be composed of letters, digits, and underscores
  • attribute GPS_time:_Encoding should begin with a letter and be composed of letters, digits, and underscores
§2.6 Attributes
  • §2.6.1 Conventions global attribute does not contain "CF-1.6"

Corrective Actions

| 46
Name Reasoning
variable "ATM_fCO2_wet" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "ATM_pCO2_wet" missing the following attributes:
  • coverage_content_type
variable "ATM_pressure_for_ATM_xCO2" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "C1Amp" missing the following attributes:
  • coverage_content_type
  • standard_name
  • units
variable "C1RPh" missing the following attributes:
  • coverage_content_type
  • standard_name
  • units
variable "C2Amp" missing the following attributes:
  • coverage_content_type
  • standard_name
  • units
variable "C2RPh" missing the following attributes:
  • coverage_content_type
  • standard_name
  • units
variable "CO2_abs" missing the following attributes:
  • coverage_content_type
  • standard_name
  • units
variable "CO2_ppm" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "Cal_Phase" missing the following attributes:
  • coverage_content_type
  • standard_name
  • units
variable "H2O_abs" missing the following attributes:
  • coverage_content_type
  • standard_name
  • units
variable "H2O_flow" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "H2O_ppm" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "Intake_T" missing the following attributes:
  • coverage_content_type
variable "LICOR_flow" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "LICOR_pressure_mbar" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "LICOR_temp_deg_C" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "O2" missing the following attributes:
  • coverage_content_type
variable "O2_Temp" missing the following attributes:
  • coverage_content_type
variable "O2sol" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "Raw_Temp" missing the following attributes:
  • coverage_content_type
  • standard_name
  • units
variable "SW_fCO2_wet" missing the following attributes:
  • coverage_content_type
variable "SW_pCO2_wet_SST" missing the following attributes:
  • coverage_content_type
variable "SW_pCO2_wet_equil_T" missing the following attributes:
  • coverage_content_type
variable "TCPhase" missing the following attributes:
  • coverage_content_type
  • standard_name
  • units
variable "TSG_Conductivity" missing the following attributes:
  • coverage_content_type
variable "TSG_Salinity" missing the following attributes:
  • coverage_content_type
variable "TSG_T" missing the following attributes:
  • coverage_content_type
variable "Type_code" missing the following attributes:
  • coverage_content_type
  • standard_name
  • units
variable "atm_moisture_sensor" missing the following attributes:
  • coverage_content_type
  • standard_name
  • units
variable "calibrated_ATM_xCO2_dry" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "calibrated_SW_xCO2_dry" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "cond_temp" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "deck_pressure" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "delta_O2" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "drip_sensor" missing the following attributes:
  • coverage_content_type
  • standard_name
  • units
variable "dry_box_temp" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "equ_differential_pressure_mbar" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "equ_pump_speed" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "equ_temp" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "equil_moisture_sensor" missing the following attributes:
  • coverage_content_type
  • standard_name
  • units
variable "equilibrator_pressure" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "raw_O2_Sat" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "raw_O2_uM" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "std_val" missing the following attributes:
  • coverage_content_type
  • standard_name
variable "vent_flow" missing the following attributes:
  • coverage_content_type
  • standard_name
| 1
Name Reasoning
Global Attributes
  • acknowledgment/acknowledgement not present
  • processing_level not present
  • geospatial_bounds not present
  • geospatial_vertical_min not present
  • geospatial_vertical_max not present
  • time_coverage_duration not present
  • time_coverage_resolution not present
  • geospatial_vertical_positive not present
  • geospatial_bounds_crs not present
  • geospatial_bounds_vertical_crs not present
  • source not present